GENERATOR MALFUNCTIONS AS INDICATED BY BATTERY/GENERATOR
INDICATORContinued
0025 00
A3Y
1. Has regulator been replaced?
YES
NO
A3YN
1. Replace regulator (WP 0257 00).
2. Verify no faults found.
A4Y
1. Replace generator (WP 0255 00).
2. Verify no faults found.
BY
1. Disconnect battery ground strap/lead(s) (WP 0337 00),
(WP 0338 00), or (WP 0339 00).
2. Remove harness 12349873 plug (1) from harness 12349881 jack
(2).
3. Inspect plugs and jacks for damage or corrosion.
4. Are plugs and jacks free from corrosion and damage?
YES
NO
BYN
1. Replace harness 12349873.(See
Table of Contents).
2. Verify no faults found.
0025 00-3