TM 9-2350-277-20-1GENERATOR MALFUNCTIONS AS INDICATED BY BATTERY/GENERATORINDICATOR0025 00INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)STE/ICE Test Set (WP 0926 00, Item 61)Jumper WirePersonnel RequiredUnit MechanicHelper (H)ReferencesSee your -10TM 9-4910-571-12&PEquipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Trim vane lowered (see your -10)Power plant access door open (see your -10)Driver’s power plant access panelremoved (see your -10)T1. Perform STE/ICE test 67 battery voltage (engine at 1200 RPM;service lights on) (WP 0124 00).2. Does VTM read more than 29 volts or less than 26 volts?YESNOTN1. Go to battery/generator indicatormalfunctions (WP 0051 00).Y1. Does VTM read less than 29 volts?YESNOGO TO AY (PAGE 0025 00-2)2Y1. Perform STE/ICE test 82 generator output voltage (WP 0133 00).2. Does VTM read less than 26 volts?YESNOGO TO BY (PAGE 0025 00-3)3Y1. Perform STE/ICE test 83 generator field voltage (engine at 1200RPM; service lights on) (WP 0134 00).2. Does VTM read within one volt of the reading obtained whenrunning STE test 67 in block T above?YESNOGO TO CY (PAGE 0025 00-6)0025 00-1