TM 9-2350-277-20-1
GENERATOR MALFUNCTIONS AS INDICATED BY BATTERY/GENERATOR
INDICATOR
0025 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
STE/ICE Test Set (WP 0926 00, Item 61)
Jumper Wire
Personnel Required
Unit Mechanic
Helper (H)
References
See your -10
TM 9-4910-571-12&P
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Trim vane lowered (see your -10)
Power plant access door open (see your -10)
Drivers power plant access panel
removed (see your -10)
T
1. Perform STE/ICE test 67 battery voltage (engine at 1200 RPM;
service lights on) (WP 0124 00).
2. Does VTM read more than 29 volts or less than 26 volts?
YES
NO
TN
1. Go to battery/generator indicator
malfunctions (WP 0051 00).
Y
1. Does VTM read less than 29 volts?
YES
NO
GO TO AY (PAGE 0025 00-2)
2Y
1. Perform STE/ICE test 82 generator output voltage (WP 0133 00).
2. Does VTM read less than 26 volts?
YES
NO
GO TO BY (PAGE 0025 00-3)
3Y
1. Perform STE/ICE test 83 generator field voltage (engine at 1200
RPM; service lights on) (WP 0134 00).
2. Does VTM read within one volt of the reading obtained when
running STE test 67 in block T above?
YES
NO
GO TO CY (PAGE 0025 00-6)
0025 00-1