VANE AXIAL COOLING FAN ASSEMBLIES REPAIR (CONTINUED)
DISASSEMBLY
A Remove nut (1), key washer (2) and impeller (3) from
housing (4).
NOTE
Do not disassemble or try to repair impeller. It is
J
dynamically balanced and spin teste to 10,000
rpm. If impeller is damaged, replace with iden-
tical part number impeller.
B
Remove 12 socket head screws (5) and 12 flat washers (6).
NOTE
Retain shims. Use to obtain tolerances during
assembly (p 5-25).
c
Remove fan drive gear box assembly (7) and shim (8).
D Remove six screws (9) and retaining plate (10).
NOTE
Do not discard items unless damaged.
E
Remove six screws (11) and six lockwashers (12).
F
Remove gland assembly (13).
G Remove six screws (14) and six lockwashers (15).
H Remove gear shaft (16) and retaining plate (17).
I
Remove two bearings (18), shield (19), spacer (20) and bear-
ing (21) from gland (22).
5-19