STACKER SOLENOID VALVE WIRING HARNESS (12332677-1): REMOVAL, DISASSEMBLY, ASSEMBLY AND INSTALLATION
A
B
c
D
E
F
WARNING
Turn OFF MASTER switch. Disconnect battery
ground cables.
Disconnect cable 12330259 plug (1) from receptacle (2).
Remove screw (3), two lockwashers (4) and disconnect GND
wires (5) from hydraulic panel (6).
Disconnect harness plug (7) from stacker solenoid (8).
Disconnect circuit 10 connector (9) from 12330252
connector (10).
cable
Remove four screws (11), four lockwashers (12), four flat
washers (13), four nuts (14) and remove receptacle, (2) and
harness from hydraulic panel.
Remove screw (15), lockwasher (16) and flat washer (17)
from strap 18).
TA311154
6-123