DRIVERS BULKHEAD TO APU VOLTAGE REGULATOR CABLE (12330256): REMOVAL AND INSTALLATION (CONTINUED)
C Disconnect cable plug (8) from APU voltage regulator (9).
D
Disconnect lead connector (10) from harness 12330248 lead (11).
E
Remove cable ground lug (12) from APU voltage regulator (9)
by removing screw (13) and lockwasher (14). Discard
lockwasher.
INSTALLATION
A
Install cable ground lug (12) to APU voltage regulator (9) by
installing screw (13) and new lockwasher (14).
B
Connect lead connector (10) to harness 12330248 lead (11).
C Connect cable plug (8) to APU voltage regulator (9).
D
Install cable (1) with two retaining straps (4) by installing
screw (5), lockwasher (6) and flat washer (7).
E Connect cable (1) plug (2) to drivers bulkhead receptacle (3).
LEFT WALL DRIVERS COMPARTMENT
TA57616
6-119
Change 2