IAPU CONTROL BOX TO APU VOLTAGE REGULATOR CABLE ASSEMBLY (12330248): REMOVAL, DISASSEMBLY, ASSEMBLY AND INSTALLATION(CONTINUED)FORWARD BULKHEAD CREW COMPARTMENTASSEMBLYA Reassemble wiring branches.B Regroup wiring branches and secure with electrical tape (item 60, AppxD).INSTALLATIONA Install cable assembly (1) to vehicle.B Install APU control box (p 13-35).C Install four retaining straps (40), four flat washers (39), four lockwashers(38) and four Screws (37).D Install two harness guards (36), seven flat washers (35), seven newlockwashers (34) and seven screws (33).E Install one flat washer (32), new lockwasher (31) and screw (30) on eachof two retaining strap assemblies (29).F Install harness (1) with flat washer (28), new lockwasher (27) and screw(26) on each of two retaining strap assemblies (25).G Install retaining strap (24), flat washer (23), new lockwasher (22) andscrew (21).H Connect APU fuel pump connectors (18 and 19) to APU fuel pump leads(20).IConnect APU power feed plug (16) to harness 12330257 receptacle (17).6-116.1/(6-116.2 blank)Change 4TM 9-2350-267-20