INITIAL SETUPSTE/lCE TEST NO. 74 STARTER CIRCUIT RESISTANCEReferences:TM 9-4910-571-12&PEquipment Condition:STE/ICE hooked Up to DCA.All electrical accessories turned off.Vehicle blocked.ABCDEFGHIJKDial test select (1) to 60.Press and release test button (2). Display (3) will indicate VEH.Dial test select (1) to 11.Press and release test button (2). Display (3) will indicate 11.Dial test select (1) to 74.Press test button (2) until display (3) shows CAL. Release testbutton (2).Check display (3).1 If display shows between ± 225, press and release testbutton.2 If display shows less than – 225 or more than + 225, referto TM 9-4910-571-12&P.Crank engine when display (3) reads GO.Stop cranking engine when display (3) reads OFF.Check display (3).NOTEDisplay reading is given in milliohms.Test No. 74 passes if display reads 3-25 milliohms.Return to troubleshooting.TA3126712-48.35Change 1TM 9-2350-267-20