2-48.32
Change 1
TM 9-2350-267-20
STE/lCE TEST NO. 71 CRANKING CURRENT (CONTINUED)
D Crank engine.
1 Pull FUEL SHUTOFF lever (4) to OFF position. Engine
must not start while performing this step.
2 Set MASTER switch (5) to ON position.
3 Push and hold ENGINE STARTER switch (6) to START
position for 5-10 seconds.
E
Check display (3).
Test No. 71 passes if display reads 350 to 550 amps.
F
Move MASTER switch (5) to OFF position.
G Return to troubleshooting.
TA312668