14-8
Change 4
TM 9-2350-267-20
AIR OUTLET ORIFICE CONNECTOR: REMOVAL AND INSTALLATION
REMOVAL
A Remove hose assembly (1) from connector (2).
B Remove external retaining ring (3) (hidden).
D Remove screw (5) and lockwasher (6). Discard lockwasher.
E Remove bracke (4).
INSTALLATION
Reverse removal procedure using new lockwasher.
HOSE ASSEMBLIES: REMOVAL, CLEANING, INSPECTION AND INSTALLATION
REMOVAL
A Loosen two clamps (1)
B
Pull hose (2) free from adapter (3) and coupling half (4).
CLEANING
Clean hose (2) with warm soapy water. Wipe or air-dry.
INSPECTION
A Inspect hose clamps (1) and coupling halves (4) for damage and wear.
B
Inspect hose (2) for damage, deterioration and evidence of dry rot.