14-6
Change 4
TM 9-2350-267-20
M2A2 AIR PURIFIER: REMOVAL, DISASSEMBLY, CLEANING, INSPECTION AND REPAIR, ASSEMBLY AND INSTALLATION (CONTINUED)
INSTALLATION
A
B
C
D
E
F
G
H
Install bracket (18) and one end of gmund lead (22) with four screws (23) and
five new lockwashers (24).
Place purifier assembly (16) on bracket (18) and install ground wire (22)
terminal with new (20) and new lockwasher (21).
Lift strap (17) and install air purifier assembly (16) in bracket (18) and secure
with strap (17).
Install elbow connector (19) in purifier assembly (16).
Install hoses (12, 13, 14 and 15) on manifold connection of air purifier (16).
Reconnect air hose (10) to air outlet connector (11).
Install shims (9) (if applicable) and guard (8) to vehicle floor with screw (5),
new lockwasher (6) and flat washer (7).
Secure guard (8) and shims (9) to canister rack with two screws (1), four flat
washers (2), two new lockwashers (3) and two nuts (4).