TM 9-2350-261-3416.Remove eight nuts (1), washers (2), andscrews (3). Separate master switch panelassembly (4) from distribution box (5).16.1. Remove circuit 2A lead (13/19) and circuit2 lead (16/18) from master switch panelassembly (see your -20).NOTEThe distribution boxes shown below areM113A2 configuration. Your distributionbox may have leads not shown here,Remove and install those leads as neededto do steps 17 thru 20 below.17.Remove screw (6), lockwasher (7), andcircuit 6 lead (8) from bus bar (9).Remove circuit 6 lead and grommet (10)from distribution box (5). Discard grommetand lockwasher.18. On 100 amp generator system, removescrew (11), lockwasher (12), and circuit 3lead (13) from circuit breaker (14). Removecircuit 3 lead and grommet (15) fromdistribution box (5). Discard grommet andlockwasher.19. On 100 amp generator system, removecircuit 2 lead (16) from master switch panelassembly (see your -20). Remove circuit 2lead and grommet (17) from distributionbox (5). Discard grommet.20. On 200 amp generator system, removecircuit 2 lead (18) and circuit 2A lead (19)from master switch panel assembly(see your -20). Remove circuit 2 lead, circuit2A lead, and two grommets (20 and 21)from distribution box (5). Discard grommets.6-20Change 4