21.22.23.Install circuit 74A lead (1) and two new24. Connect circuit lB lead (10) to generatorlockwashers (2) on starter solenoid (3).field switch (11) on secondary fuel filter.Secure with nut (4).Install circuit 6 lead (5) and two newlockwashers (6) on solenoid (3). Secure withnut (7).Connect circuit 34 lead (8) to engine low oilF O L L O W - T H R O U G H S T E P S1.2.3.4.Connect battery ground lead (see your -20).5.Install power plant rear access panel6.(see your –20).Start engine (see your -10). Check that7.power plant wiring harness works correctly.Raise and lock ramp (see your -10).Stop/shutdown engine (see your -10).Close power plant front access door and raisetrim vane (see your –10).Install hull bottom access cover(see your –20).END OF TASK6-17T M 9 - 2 3 5 0 - 2 6 1 - 3 4P R E S S U R E S W I T C H ( 9 )