TM 9-2350-261-34110.111.112.Connect power plant wiring harness circuit33 lead (1) to coolant temperature sendingunit (2).Connect three ground leads (3) to air boxheater bracket (4). Secure with screw (5)and new lockwasher (6).Connect power plant wiring harness circuit406 lead (7) to air box heater wiringharness connector (8).113.114.115.Apply a thin coat of sealant (item 70) toboth sides of gasket (9) before assembly.Apply a thin coat of antiseize compound tocleaned threads of screws (10).Install new gasket (9) and oil cooler elbow(11) on engine. Secure with two screws(10) and new key washers (12).3 - 5 0 C h a n g e 1