TM 9-2350-261-34
110.
111.
112.
Connect power plant wiring harness circuit
33 lead (1) to coolant temperature sending
unit (2).
Connect three ground leads (3) to air box
heater bracket (4). Secure with screw (5)
and new lockwasher (6).
Connect power plant wiring harness circuit
406 lead (7) to air box heater wiring
harness connector (8).
113.
114.
115.
Apply a thin coat of sealant (item 70) to
both sides of gasket (9) before assembly.
Apply a thin coat of antiseize compound to
cleaned threads of screws (10).
Install new gasket (9) and oil cooler elbow
(11) on engine. Secure with two screws
(10) and new key washers (12).
3 - 5 0 C h a n g e 1