TM 9-2350-261-20-4
REPLACE POWER CONTROL ENCLOSURE CIRCUIT 44A
LEAD (M1068 ONLY)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Personnel Required
Maintenance Level
Power-Generation Equipment Repairer 52D10
Unit
Equipment Condition
Tools and Special Tools
Engine stopped (see your -10)
Carrier blocked (see your -10)
Materials/Parts
All external power disconnected (TM 11-7010-256-
Locknut (4)
12&P)
Lockwasher (10)
Battery ground lead disconnected (WP 0294 00)
Tie strap (AR)
REMOVAL
1.
Remove ten screws (1) and lockwashers (2), and lower faceplate (3). Discard lockwashers.
2.
Remove nut (4), lockwasher (5), and lead 44A (6) from terminal X1 of relay K6 (7). Do not discard lockwasher.
3.
Remove tie straps (8) holding lead 44A (6) to other leads. Discard tie straps.
4.
Disconnect cable plug W38 P7 (9) from power control enclosure jack J28 (10).
5.
Remove four screws (11), locknuts (12), and connector J28 (10) with lead 44A (6) from power control enclosure (13).
Discard locknuts.