TM 9-2350-261-20-4
REPLACE M3 NBC HEATER HOSES AND FITTINGS (M113A2 AMBULANCE
0685 00
ONLY) -- Continued
5.
Cut and remove all tie straps (1) securing electrical leads (2) to right inlet hoses (3) and (4). Discard tie straps.
6.
Remove screw (5), lockwasher (6), and clamp (7) from top plate. Remove clamp from patient's lower right inlet hose
(3). Discard lockwasher.
7.
Remove screw (8), lockwasher (9), and clamp (10) from top plate. Remove clamp from patient's upper right inlet hose
(4). Discard lockwasher.
8.
Loosen two clamps (11) on patient's lower right inlet hose (3). Remove hose from lower right heater (12) and Y-fitting
(13).
9.
Loosen two clamps (14) on patient's upper right inlet hose (4). Remove hose from upper right heater (15) and Y-fitting
(13).
10. Loosen clamp (16) on right inlet hose (17). Remove hose from Y-fitting (13).
11. Cut and remove all tie straps (18) securing wiring harness (19) to right inlet hose (17). Discard tie straps.
12. Remove four screws (20), lockwashers (21), and clamps (22) from top plate. Remove clamps from right inlet hose
(17). Discard lockwashers.
13. Loosen clamp (23) on right inlet hose (17). Remove hose from air purifier (24).
14. Loosen clamp (25) on patient's left rear outlet hose (26). Remove hose from left rear heater (27), three spring clips
(28), and left bracket (29).
15. Loosen clamp (30) on patient's left forward outlet hose (31). Remove hose from left forward heater (32), three spring
clips (33), and left bracket (29).
16. If left bracket (29) is damaged, remove two screws (34), lockwashers (35), and bracket from top plate. Discard
lockwashers.
17. If any spring clip (28) or (33) is damaged, remove screw (36), lockwasher (37), and damaged clip from front bulkhead
and top plate. Discard lockwashers.
0685 00-3