TM 9-2350-261-20-4
REPLACE M3 NBC HEATER HOSES AND FITTINGS (M113A2 AMBULANCE
0685 00
ONLY) -- Continued
27. If removed, install spring clips (1) on top plate with screws (2) and new lockwashers (3).
28. If removed, install right bracket (4) on top plate with two screws (5) and new lockwashers (6).
29. Install clamp (7) and patient's upper right outlet hose (8) on upper right heater (9), three spring clips (1), and right
bracket (4). Tighten clamp.
30. Install clamp (10) and patient's lower right outlet hose (11) on lower right heater (12), three spring clips (1), and right
bracket (4). Tighten clamp.
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Check air flow of NBC system. See TM 3-6680-316-10.
END OF TASK
0685 00-7/8 blank