TM 9-2350-261-20-4
REPLACE IGNITER
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Maintenance Level
Equipment Condition
Unit
Engine stopped (see your -10)
Carrier blocked (see your -10)
Tools and Special Tools
Trim vane lowered (see your -10)
Power plant access door open (see your -10)
Materials/Parts
Battery ground lead disconnected (WP 0294 00)
Gasket
Lockwasher
Personnel Required
Unit Mechanic
REMOVAL
1.
Loosen four nuts (1). Turn cover plate (2) to the left and remove.
2.
Remove screw (3), lockwasher (4), igniter ground lead (5), and ground strap (6) from coolant heater. Discard lockwasher.
3.
Remove two nuts (7) and resistor strap (8) from igniter (9). Bend strap out of way.
4.
Remove igniter (9) and gasket (10) from heater. Discard gasket.
INSPECTION
1.
Check ground strap. Replace igniter if strap is worn or broken.