TM 9-2350-261-20-4
REPLACE ELECTRONIC EQUIPMENT HEATER CONTROL BOX-TO-FUEL
0632 00
PUMP LEAD (M577A2 ONLY) -- Continued
REMOVAL
1.
Disconnect circuit 402A lead (1) from wiring harness lead (2).
2.
Disconnect circuit 402A lead (1) from fuel pump lead (3).
3.
Remove five screws (4) clamps (5), and lead (1) from forward bulkhead weldnuts.
4.
Remove ten clips (6) and lead (1) from compartment roof cradles.
5.
Remove six clips (7) and lead (1) from rear bulkhead cradles.
6.
Remove two screws (8), clamps (9), and lead (1) from floor weldnuts.
7.
Remove five clamps (5) and two clamps (9) from lead (1). Remove lead from carrier.