TM9-4350-261-20-24. Disconnect three power plant wiring harnessconnectors (1) from driver’s compartment5.6.7.8.bulkhead.The differential is heavy.Have helper help you or usea lifting device.Attach a suitable lifting device of at least600 lb. (227 kg) capacity and lifting sling(2) to two differential lifting eyes.Remove three retaining clips (3) and threepins (4) from differential hull mounts.Remove differential (5) from carrier.Remove three mounts (6) from differential(5), using remover and replacer (7).I N S T A L L9.10.11.12.13.14.Install three mounts (6) in differential (5).Use remover and replacer (7).Attach a suitable lifting device of at least500 lb. (227 kg) capacity and lifting sling(2) to two differential lifting eyes.Lower differential into carrier.Install three pins (4) through differentialand hull mounts. Secure with three retain-ing clips (3) Remove lifting sling (2) from differential (5).connect threeconnectors (1)bulkhead.power plant wiring harnessat driver’s compartmentGO TO NEXT PAGE21-21w a r n i n g