TM 9-2350-261-20-2CLEAN, INSPECT, AND REPAIR62. Check harness for continuity. Usemultimeter.63. Repair harness (page 14-3).INSTALL64.65.66.67.Install harness in carrier.Install circuit 450 and 450B leads (1 and 2)and two new grommets (3) in distributionbox (4).Connect circuit 450B lead (2) to uppercircuit breaker (5).68.69.Connect circuit 450 lead (1) to lower circuitbreaker (6).Install circuit 400 lead (7) and newgrommet (8) in distribution box (4).Install circuit 6, 2, and 400 leads70.71.(9, 10, and 7) on bus bar (11) onMASTER SWITCH (12). Secure withscrew (13) and new locknut (14).N O T EInspect gasket on distribution box.Replace if damaged.Install master switch panel (15) ondistribution box (4). Secure with eightscrews (16), washers (17), and newlocknuts (18).Connect circuit 37 lead (19) to masterswitch panel lead (20).GO TO NEXT PAGEChange 212-118.11