TM 9-2350-261-20-2
CLEAN, INSPECT, AND REPAIR
62. Check harness for continuity. Use
multimeter.
63. Repair harness (page 14-3).
INSTALL
64.
65.
66.
67.
Install harness in carrier.
Install circuit 450 and 450B leads (1 and 2)
and two new grommets (3) in distribution
box (4).
Connect circuit 450B lead (2) to upper
circuit breaker (5).
68.
69.
Connect circuit 450 lead (1) to lower circuit
breaker (6).
Install circuit 400 lead (7) and new
grommet (8) in distribution box (4).
Install circuit 6, 2, and 400 leads
70.
71.
(9, 10, and 7) on bus bar (11) on
MASTER SWITCH (12). Secure with
screw (13) and new locknut (14).
N O T E
Inspect gasket on distribution box.
Replace if damaged.
Install master switch panel (15) on
distribution box (4). Secure with eight
screws (16), washers (17), and new
locknuts (18).
Connect circuit 37 lead (19) to master
switch panel lead (20).
GO TO NEXT PAGE
Change 2
12-118.11