41. Close thermostat housing valves (1).
NOTE
Use coolant in cooling system at all times.
It will reduce corrosion in engine block
and cooling will provide low temperature
protection. Mix coolant and clean water
based on the requirements for your
carrier. Use tester.
42. Fill cooling system slowly with 14 gallons
(53 liters) of coolant and water until level is
within 1/2 inch (13 mm) of filler neck
(page 3-5).
49. Replace coolant filler cap (see your -10).
WARNING
Carbon monoxide is poison-
ous and can kill you. Do not
idle engine with power
plant access panels off
unless there is a VERY
GOOD AIR FLOW.
44. Connect battery ground lead (page 13-2).
45. Start engine (see your -10). Check that
power plant grill is installed properly and
the cooling system does not leak.
WARNING
Hot radiator coolant can
burn you.
Use hand to
remove cap ONLY if cool to
touch. Turn cap slowly to
release pressure. Replace
cap by pressing down and
turning until tight.
46. Check coolant level (see your -10).
FOLLOW-THROUGH STEPS
1. Engine stopped/shutdown (see your -10).
4.
2. Install power plant rear access panel
(page 24-27 or 24-29).
5.
3. Install drivers power plant access panel
6.
(page 24-25).
Close power plant front access door
(see your -10).
Raise trim vane (see your -10).
Install generator set (M577A2 only)
(see your -10).
END OF TASK
5-10