TM 9-2350-261-20-1
Secure power plant front access door (1) in
open position with door brace (2).
Secure grill (3) to hulI with 13 screws (4)
and washers (5). Tighten 13 screws to
100-120 lb-ft (136-163 Nm) torque. Use
torque wrench (Item 97).
Install lifting eye screw (6) on lifting eye (7)
and hull. Tighten lifting eye screw to
176-200 lb-ft (237-271 Nm) torque. Use
torque wrench (Item 98)
set.
and socket wrench
26.
27.
On M577A2 only, position generator enclo-
sure (8) on hull with davit used to lift gen-
erator (see your -10).
On M577A2 only, secure generator enclosure
(8) to hull with six screws (9), eight
washers (10), and two new locknuts (11).
Tighten four screws that secure rear
enclosure to hull to 56-60 Ib-ft (75-81 Nm)
torque. Use torque wrench (Item 97).
GO TO NEXT PAGE
5-7
23.
24.
25 .