TM 9-2350-261-20-11.2.3.Turn MASTER SWITCH to OFF.Measure resistance between bilge pump body (1)and ground lead (2).Does multimeter read 0 ohms?1. Replace bilge pump(page 16-2 (front) or 16-8 (rear)).2. Verify no faults found.1. Remove BILGE PUMPS ON indicator lens (1) andbulb (2).2. Measure resistance between bulb center contact (3)and bulb base (4).3. Does multimeter read more than 5 ohms?1. Replace ground lead tobilge pump(page 16-2 or 16-8).2. Verify no faults found.1. Replace BILGE PUMPSON indicator light bulb(page 11-5).2. Verify no faults found.3-202