1. Turn MASTER SWITCH to OFF.
2. Remove instrument panel for access. See task:
remove instrument panel mounts and ground lead
(page 11-2).
3. Remove circuit 10 plug (1) and circuit 27 plug (2)
from instrument panel circuit breaker jacks (3)
and (4).
4. Measure
resistance
between circuit breaker
jacks (3 and 4).
5. Does
multimeter
read 0 ohms?
1. Replace instrument panel
circuit breaker (page 11-4).
2. Verify no faults found.