TM 9-2350-261-20-1
1. Remove instrument panel for access. See task:
remove instrument panel mounts and ground lead
(page 11-2).
2. Remove circuit 28 plug (1) from FUEL TANK
switch jack (2).
3. Remove circuit 29 or 31A plug (3) from FUEL
TANK switch jack (4).
4. Remove circuit 30 or 30A plug (5) from FUEL
TANK switch jack (6).
5. Turn FUEL TANK switch to LEFT and measure
resistance between FUEL TANK switch jack (2)
and FUEL TANK switch jack (6).
6. Turn FUEL TANK switch to RIGHT and measure
resistance between FUEL TANK switch jack (2)
and FUEL TANK switch jack (4).
7. Did multimeter read O ohms both times?
1. Replace FUEL TANK se-
lect switch (page 11-7).
2. Verify no faults found.
GO TO NEXT PAGE
3-135