TM 9-2350-261-20-11. Remove instrument panel for access. See task:remove instrument panel mounts and ground lead(page 11-2).2. Remove circuit 28 plug (1) from FUEL TANKswitch jack (2).3. Remove circuit 29 or 31A plug (3) from FUELTANK switch jack (4).4. Remove circuit 30 or 30A plug (5) from FUELTANK switch jack (6).5. Turn FUEL TANK switch to LEFT and measureresistance between FUEL TANK switch jack (2)and FUEL TANK switch jack (6).6. Turn FUEL TANK switch to RIGHT and measureresistance between FUEL TANK switch jack (2)and FUEL TANK switch jack (4).7. Did multimeter read O ohms both times?1. Replace FUEL TANK se-lect switch (page 11-7).2. Verify no faults found.GO TO NEXT PAGE3-135
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business