TM 9-2350-261-20-11. Remove jumper wire from engine harness plug.2. Install engine wiring harness on generator field switch.3. Turn MASTER SWITCH to ON.4. Measure voltage between front main harness bulkheadjack C7 (1) pin F (2) to ground.5. Turn MASTER SWITCH to OFF.6. Did multimeter read more than 17 volts?1. Repair front main wiring harness circuit 1B(page 14-3).2. Verify no faults found.1. Engine stopped/shutdown (see your -10).2. Measure resistancebetween regulator housing (1) andground.3. Does multimeter read 0 ohms?1. Install front main harnessplug C5 on regulator jack.2. Repair front main wiringharness circuit 1A(page 14-3).3. Verify no faults found.1. Remove regulator(page 9-40) and cleanground contacts(bolted surface).2. Install regulator.3. Verify no faults found.GO TO NEXT PAGEChange 43-61
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business