TM 9-2350-247-34
REPLACE INSTRUMENT PANEL WIRING HARNESS (M548A3) Continued
0021 00
REMOVAL
NOTE
Tag all leads and connectors to assist in installation.
1.
Remove screw (1), lock nut (2), washer (3), and circuit 10 lead (4) and circuit 76 lead (5) from bus bar (6) in battery box.
Discard lock nut.
2.
Disconnect circuit 450B (7) and circuit 450 (8) leads from front bilge pump circuit breaker (9) and rear bilge pump
circuit breaker (10).
0021 00-2