TM 9-2350-247-20-2
REPLACE FINAL DRIVE VENT, FILLER TUBE, AND FITTINGS (RIGHT SIDE) -- Continued
0329 00
REMOVAL
1.
Turn gauge rod (1) to the left and remove from filler tube (2).
2.
Remove screw (3) and tab washer (4). Loosen clamp (5) that secures filler tube (2) to final drive (6). Discard tab washer.
3.
Loosen nut (7) that secures filler tube (2) to elbow (8).
4.
Remove elbow (8) and preformed packing (9) from final drive (6). Discard preformed packing.
5.
Remove vent tube (10) from elbow (11).
6.
Remove elbow (11) from final drive (6).
7.
Remove filler tube (2) from final drive (6).