TM 9-2350-247-20-2
REPLACE MASTER SWITCH TO BUS BAR ELECTRICAL LEAD (M548A3) -- Continued
0270 00
REMOVAL
1.
Remove nut (1), lock washer (2), and circuit 6 lead (3) from top post (4) of master power switch (5). Discard lock washer.
2.
Remove lock nut (6), washer (7), and other end of circuit 6 lead (3) from bus bar (8). Remove circuit 6 lead (3) from
carrier. Discard lock nut.