TM 9-2350-247-20-2
REPLACE GENERATOR REGULATOR AND GROUND LEAD (M548A3)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Personnel Required
Maintenance Level
Unit Mechanic
Unit
References
Tools and Special Tools
See your -10
General Mechanic's Tool Kit (WP 0541 00, Item 57)
Materials/Parts
Equipment Condition
Lock washer (4)
Engine stopped (see your -10)
Lock washer
Carrier blocked (see your -10)
Sealing compound (WP 0542 00, Item 47)
Center seat raised (see your -10)
Sealing compound primer (WP 0542 00, Item 48)
REMOVAL
1.
Disconnect power cable (1) and regulator cable (2) from regulator (3).
2.
Remove four screws (4), lock washers (5), clamp (14), washers (6), regulator (3), and ground lead (7) from bracket (8).
Discard lock washers.
3.
Remove nut (9), terminal lead (10) of cable (11), and lock washer (12) from post (13). Discard lock washer. Replace
cable if damaged.