5.
Remove receptacle cap (1) from auxiliary power (slave) receptacle (2).
NOTE
On carriers that have early model auxiliary power receptacles, touch red lead to positive and
black lead to negative sockets in the receptacle.
6.
Place red lead (3) in positive socket of plug (4) on late model auxiliary power (slave) receptacle (2). Touch negative lead
(5) to outside of plug (2) of late model auxiliary power receptacle.
0249 00-3