TM 9-2350-247-20-2
REPLACE COOLANT PUMP (M548A3) -- Continued
0222 00
CLEANING
1.
Inspect coolant pump for evidence of leaks and rough or binding shaft and pulley. Replace coolant pump that shows any
of these defects.
INSTALLATION
1.
Install bypass tube hose (1) and hose clamps (2) on coolant pump (3).
2.
Install new gasket (4) and coolant pump (3) on oil cooler housing and secure with four flat washers (5), new lock washers
(6), cap screws (7), and one socket head screw (8).
3.
Tighten hose clamps (2).
FOLLOW-THROUGH STEPS
1.
2.
3.
4.
Install both power plant rear access panel/cover (see your -10).
END OF TASK