TM 9-2350-247-20-2
REPLACE AIR PUMP VANE KIT -- Continued
0190 00
INSTALLATION
1.
Clean air pump cavity of carbon dust.
2.
Install eccentric hub (5) and key (6) in air pump cavity.
3.
Install new vane set (4) into slots of eccentric hub (5).
4.
Install cover plate (3) on air pump end cover (2) and secure with three machine screws (1).
FOLLOW-THROUGH STEPS
1.
2.
Check air pump for proper operation (see your -10).
END OF TASK