TM 9-2350-247-20-2
SERVICE AIR CLEANER FILTER ELEMENT (M548A3)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Maintenance Level
References
Unit
See your -10
Tools and Special Tools
General Mechanic's Tool Kit (WP 0541 00, Item 57)
Industrial Goggles (WP 0541 00, Item 21)
Equipment Condition
Air Blow Gun (WP 0541 00, Item 22)
Materials/Parts
Engine stopped (see your -10)
Detergent (WP 0542 00, Item 16)
Carrier blocked (see your -10)
Suitable container
Center seat raised (see your -10)
Personnel Required
Unit Mechanic
SERVICING
WARNING
health hazards to personnel. Do not service air cleaner or vent system after NBC attack until
carrier has been decontaminated.
1.
Inspect element for frayed or deformed condition. Replace frayed or deformed element.
WARNING
Air pressure in excess of 30 psi (207 kpa) can injure personnel. Do not direct pressurized air at
yourself or others. Always wear goggles.
NOTE
Vee Pac element may be cleaned by either or both of the following methods.
2.
Using air gun, blow out element with 30 psi (207 kpa) maximum compressed air from inside to outside of element (in
direction opposite to normal air flow).