TM 9-2350-247-20-2
REPLACE AIR CLEANER INDICATOR AND HOSE (M548A3) -- Continued
0157 00
REMOVAL
1.
Disconnect indicator hose (1) from tee (2) on outlet duct (3).
2.
Remove six screws (4), washers (5), and clamps (6) from indicator hose (1).
NOTE
Do not discard gasket unless air cleaner indicator is being replaced.
3.
Remove two nuts (7), four washers (8), and two screws (9) securing air cleaner indicator (10) to mounting plate (11).
Remove gasket (12).
4.
Disconnect indicator hose (1) from adapter (13) and remove adapter from elbow (14).
5.
Remove elbow (14) from air cleaner indicator (10).
CLEANING
1.
Clean tapered pipe threads and apply a light coat of sealing compound.
2.
Clean external threads of elbow and apply a light coat of antiseize compound.
3.
Inspect elbows for damaged threads, cracks, or deformation. Replace items that show any of these defects.
4.
Inspect filter adapter for damaged threads and filter screen. Replace air cleaner indicator and adapter if adapter shows
either of these defects.
5.