TM 9-2350-247-20-1
STE/ICE-R ENGINE WILL NOT CRANK TROUBLESHOOTING
0112 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0541 00, Item 57)
Personnel Required
Unit Mechanic
References
See your -10
(WP 0010 00)
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Center seat raised (see your -10)
T
1. Engage starter switch and listen to starter.
2. Does starter sound like it is running over speed?
YES
NO
TN
1. Go to starter circuit troubleshooting
(WP 0109 00).
2. Verify no faults found.
Y
1. Remove starter (WP 0253 00).
2. Check for missing or damaged teeth on flywheel.
3. Are all teeth good?
YES
NO
YN
1. Notify your supervisor.
2Y
1. Check bendix spring, starter, or solenoid.
2. Replace parts as needed.
3. Verify no faults found.