TM 9-2350-247-20-1
STE/ICE-R BATTERY TROUBLESHOOTINGContinued
0111 00
4Y
WARNING
Battery posts and cables touched by metal objects can short
circuit and burn you. Do not wear jewelry, necklaces, or watches
when working on the electrical system. Keep tools away from
posts, wires, and terminals.
1. Batteries are OK.
2. If display shows GO, there is a bad connection in the starter
circuit. Check cables and connections to starter and repeat test.
3. If GO is still displayed, then you may have a very poor battery in
the series pair being tested. Test each battery individually.
4. If display shows .9.9.9.9., there may be a bad connection on the
battery being tested. Clean and tighten the connections on the
batteries and repeat test.
5. If display shows E013 or .9.9.9.9., the batteries being tested may
be in a discharged state. Check batteries electrolyte level; charge
batteries and repeat test.
6. If display shows E013 three consecutive times, or ----, or
.9.9.9.9. after batteries have been charged, replace battery.
7. Clamp current probe between batteries and starter.
8. Point arrow on probe toward starter.
9. Set test select switches to 72.
10. Press and release test button.
11. Is a number displayed?
YES
NO
GO TO BY (PAGE 0111 00-4)
5Y
1. Check to see if first peak current reading is within 700 to 1275
amps.
2. Is the first peak current reading within 700 to 1275 amps?
YES
NO
GO TO CY (PAGE 0111 00-5)