TM 9-2350-247-20-1POWER TAKEOFF DOES NOT ENGAGE WHEN WINCH CONTROL ISACTUATED (M548A1)0093 00INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0541 00, Item 57)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Power plant upper rear access door removed(see your -10)Center seat raised (see your -10)Center floor plates removed (WP 0394 00)T1. Check for broken winch control cable (1) on power takeoffcontrol (2) (WP 0414 00).2. Is control cable (1) properly connected?YESNOTN1. Replace or connect control cable(WP 0414 00).2. Verify no faults found.0093 00-1