FUEL LEVEL INDICATOR MALFUNCTIONS
HIGH BEAM INDICATOR LIGHT MALFUNCTIONS
TM-9-2350-247-20-1 Crane (CAB) Components Recovery Vehicle Full Tracked: light Armored M578 (2360-00-439-6242) (EIC:3LA) Manual
Page Navigation
211
212
213
214
215
216
217
218
219
220
221
TM 9-2350-247-20-1
FUEL LEVEL INDICATOR MALFUNCTIONS—Continued
0050 00
2Y
1. Turn MASTER SWITCH OFF.
2. Partially remove instrument panel (WP 0256 00).
3. Remove circuit 27A plug (1) from fuel quantity gauge jack (2).
4. Remove circuit 27 plug (3) from instrument panel
circuit breaker
jack (4).
5. Measure
continuity
between circuit 27 plug (3) and circuit 27A
plug (1).
6. Does
multimeter
read 0 ohms?
YES
NO
2YN
1. Repair instrument panel cable
assembly (WP 0294 00).
2. Verify no faults found.
3Y
1. Replace fuel quantity gauge (WP 0266 00).
2. Verify no faults found.
0050 00-2