TM 9-2350-247-20-1
FUEL LEVEL INDICATOR MALFUNCTIONSContinued
0050 00
2Y
1. Turn MASTER SWITCH OFF.
2. Partially remove instrument panel (WP 0256 00).
3. Remove circuit 27A plug (1) from fuel quantity gauge jack (2).
4. Remove circuit 27 plug (3) from instrument panel circuit breaker
jack (4).
5. Measure continuity between circuit 27 plug (3) and circuit 27A
plug (1).
6. Does multimeter read 0 ohms?
YES
NO
2YN
1. Repair instrument panel cable
assembly (WP 0294 00).
2. Verify no faults found.
3Y
1. Replace fuel quantity gauge (WP 0266 00).
2. Verify no faults found.
0050 00-2