TM 9-2350-247-20-1100 AMP CHARGING SYSTEM MALFUNCTIONS (M548A1)—Continued 0023 0010Y1. Stop engine (see your -10).2. Install regulator on regulator plate.3. Remove engine harness plug (1) from generator field switchjack (2).4. Install jumper (3) on engine harness plug (1) between pins NO (4)and C (5).5. Turn MASTER SWITCH ON.6. Measure voltage between harness plug C2 (6), pin F (7), andground.7. Does multimeter read less than 17 volts?YESNO10YN1. Replace generator field switch(WP 0288 00).2. Verify no faults found.11Y1. Turn MASTER SWITCH OFF.2. Remove engine harness plug C1 (1) from harness bulkhead jackC1 (2).3. Measure resistance between C1 plug (1), pins B (3), and F (4).4. Does multimeter read 0 ohms?YESNO11YN1. Remove jumper wire from generatorfield switch plug.2. Measure resistance between plug C1,pin F, and engine harness plug socketNO. If multimeter reads 0 ohms, seestep 4.3. Measure resistance between plug C1,pin B, and engine harness plugsocket C. If multimeter reads 0 ohms,see step 4.4. Repair engine harness circuit 1A or1B (WP 0294 00).5. Verify no faults found.0023 00-6