TM 9-2350-247-20-1
100 AMP CHARGING SYSTEM MALFUNCTIONS (M548A1)Continued
0023 00
2Y
1. Check multimeter reading.
2. Does multimeter read less than 29 volts?
YES
NO
GO TO BY (PAGE 0023 00-7)
3Y
1. Stop engine (see your -10).
2. Remove harness plug C6 (1) from generator jack (2) and harness
plug C3 (3) from regulator jack (4).
3. Inspect harness plugs C6 (1) and C3 (3), generator jack (2), and
regulator jack (4) for corrosion and damage.
4. Are plugs and jacks clean and in good condition?
YES
NO
3YN
1. Repair/replace harness and/or
generator (WP 0242 00 or
WP 0246 00).
2. Verify no faults found.
0023 00-2