TM 9-2350-247-20-1100 AMP CHARGING SYSTEM MALFUNCTIONS (M548A1)—Continued 0023 004Y1. Measure resistance between harness plug C6 (1) and plug C3 (2),sockets D (3) to B (4), C (5) to C (6), B (7) to D (8), and E (9) toE (10).2. Does multimeter read 0 ohms each time?ABCDEFGYESNO4YN1. Repair/replace harness(WP 0294 00).2. Verify no faults found.5Y1. Install harness plug C6 on generator jack.2. Remove harness plug (1) from bulkhead and plug C2 (2) fromregulator jack C2 (3).3. Inspect harness plug C2 (2) and regulator jack C2 (3) forcorrosion and damage.4. Is plug and jack in clean and good condition?YESNO5YN1. Repair/replace harness and/orregulator (WP 0294 00 orWP 0249 00).2. Verify no faults found.0023 00-3