TM 9-2350-267-10STARTING MAIN ENGINE - Continued8.9.10.11.12.13.Pull FUEL SHUT OFF handle (5) to OFFposition before checking for hydrostaticlock.Check for hydrostatic lock by intermittentlyactivating STARTER switch (with MASTERswitch ON and FUEL SHUT OFF handlepulled out).Release FUEL SHUT OFF handle (5).Place throttle control lever to idle position.If fuel filters have been drained since laststart, hold FUEL PRIME switch (6) ON for45 seconds. Release switch after allottedtime.WARNINGProtect your hearing. Due to high intensity noise, hear-ing protection is required when operating this vehicle.CAUTIONDo not operate starter continuously for over 30 sec-onds. If engine does not start, allow l-minute cool-offperiod before again engaging starter. Notify Organiza-tional Maintenance if engine fails to start on fourth try.Push and hold engine STARTER switch (7) to START until engine starts. Do notoperate continuously for over 30 seconds.2-84