TM   9-2350-267-10 PORTABLE INSTRUMENT PANEL CHECKOUT PROCEDURE Frequently check the following gages and indicators to make sure vehicle power pack continues to operate correctly. If the following normal indications are not observed during this check, refer to troubleshooting section in Chapter 3. Troubleshooting  procedures  begin  on  page  3-5. 1. MASTER WARNING lamp (1) should go out after engine has run for 15 seconds. CAUTION If  the  MASTER  WARNING  lamp  lights  during  operation,  im- mediately  check  TRANSMISSION  OIL  TEMPERATURE gage, ENGiNE WATER TRANSMISSION gage, and ENGiNE OIL PRESSURE gage (steps 4,5,6, and 7, respectively) for readings in the normal ranges. if gage readings are correct, but  iamp  stays  lit,  notify  Organizational  Maintenance. 2. COOLANT level indicator lamp (2) should be OFF. 2-86