TM 9-2350-287-20-2 17-18.   CONVEYOR   TOGGLE   CLAMP   AND   TUBE   ASSEMBLY   REPAIR   (continued). If toggle clamp handle cannot be lowered or does not put sufficient tension on tube assembly, go to step 5. If toggle clamp handle can be lowered and sufficient tension is put on tube assembly, go to step 7. 5. Raise toggle clamp handle (5) and remove hook (3) from tube assembly (2). Tighten or loosen tube assembly (2) in clevis (18) as necessary to lengthen or shorten tube assembly (2). 6. Repeat steps 4 and 5 until sufficient tension on tube assembly (2) is attained. 7. Tighten jam nut (16) against rod end (17). FOLLOW-ON   MAINTENANCE: l Stow conveyor (refer to TM 9-2350-287-10). 17-46