Page Title: c. CLEANING AND INSPECTION
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM   9-2350-287-20-2 15-29.  CANISTER  DOORS  AND  PERSONNEL  SIDE  DOOR  LATCHES  AND  BUMPER ASSEMBLIES  REPAIR  (continued). c. CLEANING AND INSPECTION 1. 2. d. 1. 2. Drycleaning  solvent  P-D-680  is  toxic  and  flammable.  Always  wear  protective  goggles and gloves, and use only in a well-ventiiatd area. Avoid contact with skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat. Clean all parts with drycleaning solvent. Make sure lubrication holes in latch assembly (16) are clean and free of  debris. Inspect all parts for cracks, bends, or other damage. Replace unserviceable parts. ASSEMBLY Install pin (12), spring (1 1), and grease fitting (13) in latch assembly (16). Install plate (10) on latch assembly (16) with four screws (8) and new Iockwashers (9). 15-67