TM 9-2350-287-20-1I2-19. TROUBLESHOOTING CHART (continued).Ix.NBC SYSTEM (continued).(1) NO FAN OPERATION FROM M2A2 AIR PURIFIER(continued).ICONTINUED FROM GG. 3. Place red lead of multimeter in wire 81socket and ground black lead.4. Turn MASTER switch ON (refer to TM 9-2350-287-10).5. Check for 24 ± 3 vdc.6. Turn MASTER switch OFF (refer to TM 9-2350-287-10).Is voltage indicated?IRepair or replace master relay box (para 7-21). Verify problem is solved.4Check batteries for charge. If batteries arefully charged, replace wire 81 (para 7-51). Ifbatteries are not fully charged, rechargethem. Verify problem is solved..END OF TASK2-372