TM 9-2350-287-20-1
2-19. TROUBLESHOOTING CHART (continued).
w. AFES, CREW (continued).
(1) POWER ON LAMP DOES NOT LIGHT WHEN
MASTER SWITCH IS TURNED ON. All other
electrical systems operate (continued).
C. 2. Disconnect wire harness 12351461 circuit
10A from number 6 circuit breaker panel no.
2.
3. Place red lead of multimeter in circuit
breaker socket and black lead to ground.
4. Check for 24 ± 3 vdc.
Repair wire 10A or replace wire harness
12351461 (para 7-77). Verify problem is
solved.
Replace circuit breaker no. 6 (para 7-11).
Verify problem is solved.
END OF TASK
2-349