TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).u. AUXILIARY POWER UNIT (continued).(1) ENGINE CRANKS BUT FAILS TO START(continued).CONTINUED FROM DD.NOTEPlunger should pull up when switch isturned ON, and should move downwhen switch is turned OFF.Does fuel solenoid plunger function property?I1Notify Direct Support maintenance.E. 1. Place red probe of multimeter on lead 421terminal at fuel solenoid and ground blackprobe.2. With the aid of an assistant turn MASTERswitch ON (refer to TM 9-2350-287-10).3. Turn APU FUEL SHUT-OFF switch ON(refer to TM 9-2350-287-10).4. Check for 24 ± 3 vdc.5. Turn MASTER switch and FUEL SHUT-OFF switch OFF (refer to TM 9-2350-287-10).Is voltage indicated?IINotify Direct Support maintenance.F. 1. Disconnect harness 12329640 connector(larger connector) at APU wall mount.2. Place red probe of multimeter on wall-mounted connector socket B and groundblack probe.Continued on next page2 - 2 94