TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).h. LIGHTS (continued).(17) PORTABLE INSTRUMENT PANEL LIGHTS FAILTO OPERATE. All other lights operate (continued).CONTINUED FROM FF.3. Turn MASTER switch ON (refer to TM 9-2350-287-10).4. Check for 24 ± 3 vdc.5. Turn MASTER switch OFF (refer to TM 9-2350-287-10).Is voltage indicated?Replace lighting switch (para 7-9). Verifyproblem is solved.G.1. Reconnect harness 12330252 to lightingswitch.2. Disconnect wire 15 of harness 12330252from wire 10L of harness 12376405 at no. 2position of circuit breaker panel no. 2.3. Place multimeter red leadground black lead.4. Turn MASTER switch ON2350-287-10).5. Check for 24 ± 3 vdc.in wire 10L and(refer to TM 9-6. Turn MASTER switch OFF (refer to TM 9-2350-287-10).Is voltage indicated?Notify Direct Support maintenance. Repair wire 10L or replace harness12376405 (para 7-57). Verify problemis solved.END OF TASK2-198